Key Helical Pile Parameters and How They Affect Your Choice

Helical piles manufactured by WINTTEK have the following parameters:

On a phone, swipe the table left or right to view all columns.

Shaft diameter, mm Pipe wall thickness, mm Helix diameter, mm Helix thickness, mm Length, mm
 57  3,5   200  3  from 1650
 76  3,5   250  4  from 1650
 89  3,5  250  4  from 1650 
 108  4,0  300  5  from 1650 
 133  4,0  350  5  from 1650

Helical pile shaft diameter (D1) and pipe wall thickness (S1).

   Helical pile shaft diameter is the diameter of the pipe used to manufacture it. Together with pipe wall thickness these are the key pile parameters that determine its load-bearing capacity. The greater the diameter and thickness, the more weight the pile can support. But we particularly stress: only when installed correctly! This means the pile must reach dense soil layers that will support the weight of the building. Otherwise, it will partly act as a friction pile, which requires a different calculation method. In service, the pile is subjected to a vertical load, which is the primary load. At the same time, it must provide resistance to bending. Shaft diameter and wall thickness therefore play an important role here too. Filling with concrete helps a little, but it should not be relied upon: its main purpose is protection against oxygen and water ingress.

 

Pile length (L).

   Length is measured from the tip of the cone to the cut end of the upper shaft. After selecting the pile diameter, its length is the most important consideration. Above all, the pile tip must be below the frost line; otherwise, it will not cope with frost-susceptible soils. We repeat: the pile must reach dense soil layers. Ultimately, the length is made up of three dimensions: first, the installation depth;  second, the height of the building plinth; and third, 150 mm to trim the upper shaft and bring the foundation to the required level. Thus, in Tambov and the surrounding region, where the standard soil freezing depth is 1,5 m, the minimum pile length is 2 metres.   

Helix diameter (D) and thickness (S).

   Many people believe that a helical pile’s helix diameter determines its ability to withstand design loads. This is incorrect. The larger the pile diameter, the greater the resistance it must overcome during installation. The soil provides the support. To avoid destroying the soil structure and thus allow the pile to advance, the helix diameter is increased in proportion to the pile diameter. The helix thickness is determined by its ability to withstand soil pressure during installation without changing shape or deforming.
   Almost all manufacturers offer piles with two helices. These are said to withstand higher loads. This is incorrect. We repeat: the pile shaft carries the load, rather than the helix, even if there are 2 or more helices or the pile has multiple turns. They have no place in the calculation method. They simply cost more and… We use them only when soil investigation results indicate the presence of quicksand, peat deposits, and similar conditions. These must be penetrated to reach dense layers, and they provide no support at all… The second helix helps achieve this by providing additional driving force.
   WINTTEK helices have a serrated edge (patented). It makes work easier in frozen ground in winter and, based on our installation experience, also helps the helix engage the soil in summer and cut through small roots.
   It should be said that helix diameter does affect the pile’s load-bearing capacity in one situation: when installation reveals that the chosen pile length is insufficient because the required layers have not been reached, and you decide to save money. The helix will help the foundation stand without settling for a little while, but after that… You should therefore understand that the helix is simply a means of getting the pile to the required depth. 

Helix pitch.

   For the customer this parameter does not matter, because it does not affect load-bearing capacity. For installers, however, it is important: it determines the effort required to screw the pile in. In principle, different soils call for different pitches. But no manufacturer can afford this… Through trial and error, we developed our own compromise rather than copying someone else’s pile parameters. The same applies to helix position, entry angle, shape, and cone design. However, for our partners we also manufacture   custom helical piles to meet their requirements. These include piles with an offset helix, because everyone uses different pile installation equipment and has different installation practices and experience.

   Consideration of all these factors, together with calculations, experiments, and service experience, has produced a table used by all helical pile manufacturers and installers.

On a phone, swipe the table left or right to view all columns.

Pile type Load-bearing capacity
per 1 pile 
Recommended spacing
between piles
Applications
Construction helical pile
СВС-57
From 1 to 1,5 tonnes from 0,5 to 2 m For lightweight structures, terraces, fences, signposts, and road signs
Construction helical pile
СВС-76
From 2 to 2,5 tonnes from 1 to 3 m For lightweight structures, terraces, fences, signposts, road signs, and piers
Construction helical pile
СВС-89
From 3,5 to 4 tonnes from 2 to 4 m For small houses (holiday homes), timber-frame houses, outbuildings, extensions, heavy fences, advertising structures, and piers
Construction helical pile
СВС-108
From 4 to 6 tonnes from 2 to 5 m For solid-timber houses, hangars, gates, pipelines, and overhead power line supports
Construction helical pile
СВС-133